Nnendress hauser fmu90 pdf

By using the linearisation function, the prosonic m can also be used for flow. With hart output, the measuring ranges can be freely adjusted and a densitycompensated level measurement can be activated. This is why our field instruments use different measuring principles to operate reliably and accurately in any situation. Transmitter in housing for field or top hat rail mounting for up to 2 ultrasonic sensors fdu9x. The free space radar micropilot fmr50 sensor offers noncontact level measurement in liquids with the timeofflight principle. But also for flow measurement in open channels and measuring weirs.

Consultation during office hours our technical experts are available to answer any questions you may have regarding our edirect products and their application. Operating instructions prosonic s fmu90 slotindex lists for profibus dp. The flowmeter with premium accuracy, robustness and custody transfer functionality. The sensors of the class fdu8x can be connected as well. Transmitter in housing for field or tophat rail mounting for the ultrasonic sensors fdu9191f92939596. The prosonic fmu44 sensor is suited for noncontact level measurement in fluids, pastes, coarse bulk material and flow measurement in open channels or at weirs. The vibration resistance of the measurement point depe nds on sensor type and construction. The liquiphant is used for overfill prevention or pump dryrun protection in cleaning systems. Used for overfill prevention or as pump dryrun protector. The prosonic s fmu90 is a transmit ter for the ultrasonic sensors fdu91, fdu91f, fdu92, fdu93, fdu95 and fdu96. Liquiphant ftl31 is a point level switch for liquids. Continuous noncontact level measurement and control. Universal hart communicator via the serial interface with the hart protocol type c. The flowmeter for smallest flow rates with integrated solids content diagnostics.

Electrical connection a minimum resistance must be present in the circuit for correct transmission of the communications signal to take place see technical data. Fmu30 twowire compact ultrasonic sensor for noncontact level measurement of fluids, pastes and bulk solids in basic applications. The waterpilot fmx21 transmitter with capacitive, oilfree ceramic measuring cell is typically used in the process and environmental applications for hydrostatic level measurement. Get promass 80 manual endress hauser pdf file for free from our online library pdf file. The cerabar pmc51 digital pressure transmitter with capacitive, oilfree ceramic measuring cell is typically used in process and hygienic applications for pressure, level, volume or mass measurement in liquids and gases. Ultrasonic sensor for level and flow measurement for connection to fmu9x measuring range up to 3m the fdu90 ultrasonic sensor for continuous, noncontact and maintenancefree level measurement of fluids, pastes, sludges and powdery to coarse bulk materials. Highest measurement performance for liquids and gases under varying, demanding process conditions. Suitable for resistance thermometer rtd and thermocouple tc device configuration using pc with configuration kit.

People for process automation offer you solutions and products in flow, level, liquid analysis, pressure, temperature measurement, software and system products. Prosonic fmu90 separated version with field housing or top hat. Prevodnik do provozu nebo pro montaz na listu az pro dva senzory fdu9091929395. Pc programmable pcp temperature head transmitter for converting various input signals into a scalable 4 to 20 ma analog output signal. The transmitter version for level measurements product structure according to section 2. The deltapilot fmb70 with the condensate resistant contite measuring cell and twochamber housing is typically used in the process and hygienic applications. Samostatna verze prosonic fmu90 v provedeni do provozu nebo pro montaz na listu pro instrumentaci ovladacich rozvadecu je vhodna pro kontinualni bezkontaktni mereni vysky hladiny kapalin, past, kalu a praskovitych az hrubozrnnych sypkych materialu. Transmitter in housing for field or top hat rail mounting for up to 2 sensors fdu9091929395. Proline promass 40e, 80e, 80f, 83e, 83f, 84f installation length in accordance with namur recommendation ne 2 special documentation the special documentation is an integral part of the following technical. Fmu 230231 ultrasonic level measurement operating instructions. Prosonic fmu95 separated version with field housing or top hat rail housing for control cabinet instrumentation are suited for continuous, noncontact level measurement of fluids, pastes, sludge and powdery to coarse bulk solids. The sensors of the former class fdu8x can be connected as well. Read online now promass 80 manual endress hauser ebook pdf at our library.

The probe and container wall conductive material form an electric. Depending on the sensor, the measuring range is up to 15 m 49 ft in fluids and up to 7 m 23 ft in bulk solids. Envelope curves on the display for quick and simple diagnosis. You can search and use the dc values for the correct commissioning of radar and capacitive measuring devices. Integrated automatical sensor detection for transmitters fmu90. It is made for level measurement in liquid and pastelike media in open or closed containers and unaffected by possible foam formation. The compact deltapilot fmb50 transmitter with the condensate resistant contite measuring cell is typically used in the process and hygienic applications. Were here for you during this unprecedented timecall or order online for the best treatment. Prosonic fmu90 separated version with field housing or top hat rail housing for control cabinet instrumentation are suited for continuous, noncontact level measurement of fluids, pastes, sludge and powdery to. The flowmeter for smallest flow rates with a modular electronic concept. Instrumentation does not always require a vast amount of consultation in terms of price and application. Prosonic s fmu90 measuring instruments pdf manual download.

Complete main electronic module or power supply, ioboard with amplifier as individual boards. Point level switch solicap s fti77 with electronic versions fei53, fei57s and fei58 for connecting to a separate switching unit. Fmu90 1 can be applied for different measuring tasks, e. Monorack housing 7 hp for single or multiple mounting in the control panel. Transmitter in housing for field or top hat rail mounting for up to 10 sensors fdu9091929395. The cerabar pmc51 digital pressure transmitter with capacitive, oilfree ceramic measuring cell is typically used in process and hygienic applications for pressure. The ftl31 is designed for industrial applications in all industries, mainly the machinery industry. Field instrumentation to measure and monitor flow, level, pressure, temperature and analyze liquids. The cerabar pmp23 is a priceattractive and compact absolute or gauge pressure transmitter. Each instruction is identified by a corresponding pictogram. It is made for level measurement in liquid and pastelike media in open or closed containers and unaffected by. Ultrasonic level measurement nivosonic fmu 673 z, fmu 678 z. Prosonic fmu90 separated version with field housing or top hat rail housing for control cabinet instrumentation are suited for continuous, noncontact level measurement of fluids, pastes, sludge and powdery to coarse bulk solids.

Digital pressure transmitter with oilfree ceramic sensor for measurement in gases or liquids. Optionally, the prosonic s fmu90 has an input for an external temperature sensor fmu90b. Install the prosonic t at a height so that the blocking distance bd is not undershot, even at maximum fill level. In order to use the hart communication, the circuit must contain a communication resistor of 250.

Cost effective device for sophisticated level measurement in liquids and bulk solids for up to 20m. Liquiphant ftl20 is a point level switch in compact design with stainless steel housing. The sensor with degree of protection ip68 type 6p enclosure and a modular electronic concept. Prosonic fmu90 ultrasonic measurement timeofflight transmitter by endress hauser ag. The transmitter fmu90 is available in a version with an input for the external temperature sensor. Continuous non contact level measurement and control. With hart output, the measuring ranges can be freely adjusted and a densitycompensated level measurement can. Depending on the application a field instrument is required to measure and control different automation processes. This temperature sensor is a temperaturesensitive platinum resistor with a resistance of 100. Our aim is to ensure peoples health and provide the best possible support to our customers worldwide. The nivosonic supplies power and the sensor sends back a digital echo signal.

Measuring system input signal a threecore installation cable connects the nivosonic fmu to the du z ultrasonic sensor. Power supply, ioboard, amplifier, board carrier, terminal connection, ribbon cable, installation marterial. The specialist in the water and wastewater industry for the most demanding applications. Flow measurement backwater and dirt detection totalizers and counters. Simple, menuguided operation with 6line plain text display. Separated version with field housing or control room instrumentation, up to 5 relays for pump control, limit switch inputs, 1 channel version.

1239 1375 283 34 1180 1072 282 49 396 1421 66 936 566 1302 553 115 1187 119 1128 1453 551 1063 1404 748 268 801 335 596 838 30 971 539 1122 1298 1180 1200